BJFTQ - PR-1432-G INORGANIC DICHROMATE PART A
- MSDS: BJFTQ
- Manufacturer: PRODUCTS RESEARCH AND CHEMICAL CORP
- Product Name: PR-1432-G INORGANIC DICHROMATE PART A
- National Stock Number: 8030-01-234-2793
Product Identification
Product ID:PR-1432-G INORGANIC DICHROMATE PART A
MSDS Date:02/03/1989
FSC:8030
NIIN:01-234-2793
Kit Part:Y
MSDS Number: BJFTQ
Responsible Party
GLENDALE, CA 91209
US
Emergency Phone: 800-228-5635
Info Phone: 818-240-2060
Preparer: JESLINE SAMSON
Cage: DO563
Contractor
Telephone: 818-240-2060
Cage: DO563
Ingredients
DIMETHYLFORMAMIDE
CAS: 68-12-2
RTECS: LQ2100000
Fraction By Weight: 30%
OSHA PEL S, 10 PPM
ACGIH TLV: S, 10 PPM; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
MAGNESIUM DICHROMATE
CAS: 13423-61-5
Fraction By Weight: 30%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.05 MG/M3
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:SKIN:OVEREXP TO HEXAVALENT CHROMIUM
OVER PEL MAY CAUSE PAINLESS PENETRATING ULCERS OF SKIN. TOXIC BY
ABSORPTION. INHALED:(MIST/DUST)IRRIT OF MUCOUS MEMBRANES. MAY CAUSE
BRONCHOASTHMA. OVEREXP OVER PEL MAY CAUSE PENETRATING ULCERS OF
MUCOUSMEMBRANES OF NOSE & PERFORATION OF CARTILAGINOUS NASAL
SEPTUM. POSS LIVER DAMAGE
Explanation of Carcinogenicity:HEXAVALENT CHROMIUM COMPOUNDS ARE LISTED
AS CARCINOGENS. (PROPOSITION 65 INCLUDES ALL HEXAVALENT CHROMIUM
COMPOUNDS)
Effects of Overexposure:EYES: IRRITATION, POSSIBLE EYE DAMAGE. SKIN:
IRRITATION, OVEREXP MAY CAUSE ALLERGIC SKIN RASH. INHALED:
IRRITATION, DIZZINESS, FATIGUE, SLEEPINESS. INGESTION: CAN IRRITATE
STOMACH & INTESTINES. CAN CA USE NAUSEA, VOMITING & DIARRHEA. LARGE
AMOUNTS CAN CAUSE LIVER & KIDNEY DAMAGE.
First Aid
First Aid:EYES: FLUSH WITH LUKE WARM WATER FOR 15 MINUTES, CONSULT
PHYSICIAN. SKIN: WASH WITH SOAP & WATER. IF SYMPTOMS PERSIST,
CONSULT A PHYSICIAN. INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS
ARE PRESENT, CO NSULT A PHYSICIAN. AND INGESTION: CONSULT A
PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:CO2, WATER FOG.
Unusual Fire/Explosion Hazard:OXIDIZER
Accidental Release
Spill Release Procedures:DIKE & COVER THE SPILL WITH A NON-OXIDIZABLE
ABSORBANT. SCOOP INTO CONTAINER. SPRINKLE SODIUM THIOSULFATE ON
RESIDUE. WORK INTO RESIDUE. SCOOP INTO DISPOSAL CONTAINER. CLEAN
AREA WITH WATER.
Handling
Handling and Storage Precautions:AVOID PROLONGED OR REPEATED SKIN
CONTACT OR BREATHING OF VAPORS. AVOID INGESTION. DUE TO TOXICITY BY
SKIN ABSORPTION, AVOID ALL SKIN CONTACT.
Other Precautions:THIS PRODUCT CONTAINS A TOXIC CHEMICAL OR CHEMICALS
SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III
OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 AND 40
CFR PART 372.
Exposure Controls
Respiratory Protection:WHEN APPLYING IN A CONFINED AREA OR DURING
SPRAYING APPLICATION OR OTHER CIRCUMSTANCES LIKELY TO PRODUCE
AIRBORNE CONTAMINATION IN EXCESS OF PEL, AIR-SUPPLIED RESPIRATOR
AND COMPLETE SKIN PROTECTION A RE RECOMMENDED.
Ventilation:GENERAL VENILATION TO MAINTAIN DUST, MIST OR VAPOR LEVELS
BELOW PEL.
Protective Gloves:NITRILE, BUTYL OR NATURAL RUBBER GLOVES
Eye Protection:CHEM GOGGLES, FULL FACE SHIELD IF SPLASH
Other Protective Equipment:GLOVES ARE NOT ADEQUATE PROTECTION FOR
IMMERSION.
Work Hygienic Practices:SKIN AREAS SUBJECT TO SPLASH SHOULD BE
PROTECTED WITH NITRILE, BUTYL OR NATURAL RUBBER, POLYETHYLENE APRON
OR COVERALLS
Supplemental Safety and Health
NOTE: STUDIES HAVE SHOWN THAT HIGH OVEREXPOSURE TO DMF IS EMBRYOTOXIC
IN LABORATORY ANIMALS. PROLONGED EXCESSIVE EXPOSURE TO DIMETHYL
FORMAMIDE MAY CAUSE TESTICULAR CANCER.
Chemical Properties
Solubility in Water:APPRECIABLE
Percent Volatiles by Volume:67
Stability
Stability Indicator/Materials to Avoid:YES
FLAMMABLE LIQUIDS.
Hazardous Decomposition Products:OXIDES OF CARBON AND NITROGEN,
CHROMIUM COMPOUNDS.
Disposal
Waste Disposal Methods:EPA WASTE NO. D-007. DISPOSE OF SPILLAGE IN
COMPLIANCE WITH FEDERAL AND STATE REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.